Search results for "Arc therapy"
showing 5 items of 5 documents
Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
2017
Abstract Introduction Aim of the present study is to evaluate homolateral and contralateral hippocampus (H-H, C-H, respectively) dose during Fractionated Stereotactic Radiotherapy (FSRT) or Radiosurgery (SRS) for brain metastases (BM). Materials & methods Patients with BM 3 months, were considered for SRS/FSRT (total dose 15–30 Gy, 1–5 fractions). For each BM, a Flattening Filter Free (FFF) Volumetric Modulated Arc Therapy (VMAT) plan was generated with one or two arcs. Hippocampi were not considered during optimizations phase and were contoured and evaluated retrospectively in terms of dose: the Dmedian, Dmean, D0.1cc and the V1Gy, V2Gy, V5Gy and V10Gy were analyzed. Results From April 2…
Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube
2020
Highlights • Line-focus X-ray tubes are suitable for clinical microbeam radiation therapy (MRT). • A modular high-voltage supply safely enables high electron beam powers. • An electron accelerator was designed to generate an eccentric focal spot. • We simulated a peak-to-valley dose ratio above 20 for single-field MRT. • Microbeam arc therapy spares healthy brain tissue compared to single-field MRT.
Dosimetric effect of respiratory motion on planned dose in whole-breast volumetric modulated arc therapy using moderate and ultra-hypofractionation.
2021
Abstract Background and purpose The interplay effect of respiratory motion on the planned dose in free-breathing right-sided whole-breast irradiation (WBI) were studied by simulating hypofractionated VMAT treatment courses. Materials and methods Ten patients with phase-triggered 4D-CT images were included in the study. VMAT plans targeting the right breast were created retrospectively with moderately hypofractionated (40.05 Gy in 15 fractions of 2.67 Gy) and ultra-hypofractionated (26 Gy 5 fractions of 5.2 Gy) schemes. 3D-CRT plans were generated as a reference. All plans were divided into respiratory phase-specific plans and calculated in the corresponding phase images. Fraction-specific d…
Adjuvant volumetric-modulated arc therapy with simultaneous integrated boost in endometrial cancer. Planning and toxicity comparison
2014
Objective. To report dosimetric and acute toxicity data in prospectively enrolled high-intermediate risk endometrial cancer (HIR-EC) patients postoperatively irradiated by simultaneous integrated boost volumetric modulated arc therapy (SIB-VMAT). Methods. Thirty prospectively enrolled HIR-EC patients were postoperatively treated by SIB-VMAT. Target coverage, dose homogeneity, and sparing of organs at risk (OARs) were compared with corresponding data retrieved from an historical control (30 consecutive selected matched patients) treated by concomitant boost three-dimensional conformal radiotherapy (3D CRT CB) from a previously published study (ADA-I trial). All patients received 45 Gy on pel…
Weekly Cisplatin and Volumetric-Modulated Arc Therapy With Simultaneous Integrated Boost for Radical Treatment of Advanced Cervical Cancer in Elderly…
2016
Background: To evaluate the feasibility and clinical preliminary results of weekly cisplatin and volumetric-modulated arc therapy to the pelvis with simultaneous integrated boost to macroscopic disease in a cohort of elderly patients. Materials and Methods: Inclusion criteria of this prospective study were age ≥70 years, Karnofsky performance status 70 to 100, locally advanced histologically proven squamous cervical carcinoma, and patients unable to undergo brachytherapy. Radiation doses prescribed were 66 Gy to the macroscopic disease and 54 Gy to the pelvic nodes in 30 fractions. Weekly cisplatin dose was 40 mg/mq. Results: A total of 30 patients were recruited. Median follow-up was 32 mo…